Skip to content

What are the two types of electrosurgery? An in-depth guide

3 min read

Electrosurgery is a medical technique used in over 80% of all surgeries for cutting and coagulation. A firm understanding of the electrical principles and the two primary modalities—monopolar and bipolar—is essential for any medical professional involved in surgical procedures to ensure patient safety and effectiveness.

Quick Summary

The two primary types of electrosurgery are monopolar and bipolar, differing fundamentally in how the electrical circuit is completed. Monopolar electrosurgery uses a single active electrode and a dispersive pad to send current through the patient's body, while bipolar electrosurgery confines the current entirely within the instrument, such as forceps, for highly localized tissue effects.

Key Points

  • Monopolar Circuit: Current flows from an active electrode, through the patient's body, and to a distant dispersive pad.

  • Bipolar Circuit: Current is confined to the tissue grasped between two electrodes on the same instrument, eliminating the need for a dispersive pad.

  • Versatility vs. Precision: Monopolar is favored for its versatility across large areas, while bipolar is used for pinpoint, precise coagulation.

  • Patient Safety: Bipolar electrosurgery is significantly safer for patients with electronic implants, like pacemakers, as the current does not pass through the body.

  • Applications: Monopolar is suitable for large-area cutting and dissection, while bipolar excels at delicate hemostasis.

  • Modern Innovations: Advanced electrosurgical units feature feedback systems and integrated cutting capabilities to improve safety and control for both techniques.

In This Article

The Core Principles of Electrosurgery

Electrosurgery uses high-frequency alternating electrical current to generate heat in tissue, allowing for precision cutting, coagulation, desiccation, and fulguration. Unlike electrocautery, which uses a direct current to heat a probe applied to the tissue, electrosurgery passes the current through the tissue itself. The key difference between electrosurgery's two types lies in the path the electrical current takes to complete its circuit.

Monopolar Electrosurgery

Monopolar electrosurgery is the most common and versatile form of electrosurgery. The electrical circuit includes an electrosurgical generator (ESU), an active electrode applied to the target tissue, the patient's body through which the current travels, and a dispersive electrode (return pad) placed elsewhere on the body to return the current to the generator. The current is concentrated at the active electrode for surgical effect and dispersed over the large area of the return pad to prevent burns.

Advantages of Monopolar Electrosurgery

  • Versatility: Effective for a variety of procedures and large areas.
  • Rapid Effects: Achieves rapid cutting and coagulation.
  • Accessibility: Allows work in wider surgical fields.

Disadvantages and Risks

  • Risk of Burns: Requires careful return pad placement to avoid alternate site burns.
  • Potential for Interference: Can affect patients with implantable electronic devices.
  • Insulation Failure: Increased risk due to the current's path through the body.

Bipolar Electrosurgery

Bipolar electrosurgery confines the electrical current to a small, isolated area of tissue using an instrument like forceps where one tip is the active electrode and the other is the return electrode. The current passes only through the tissue grasped between the tips, completing the circuit locally and eliminating the need for a dispersive pad.

Advantages of Bipolar Electrosurgery

  • Enhanced Safety: Reduces the risk of burns and complications related to current passing through the body.
  • Greater Precision: Offers excellent control for delicate procedures.
  • Safe for Patients with Implants: Preferred for patients with pacemakers or other medical devices.

Disadvantages

  • Limited Application: Less effective for large-area cutting.
  • Cannot Cut Tissue: Primarily used for coagulation and hemostasis.
  • Requires Precise Grasping: Effectiveness depends on proper tissue grasping.

Comparing Monopolar and Bipolar Electrosurgery

Feature Monopolar Electrosurgery Bipolar Electrosurgery
Current Path Through the patient's body to a dispersive pad Confined to the tissue between the instrument's tips
Electrodes One active electrode and one large, dispersive return pad Two electrodes on the same instrument (e.g., forceps)
Application Versatile for cutting, coagulating large areas, and extensive dissection Precise coagulation of small areas, especially delicate tissues
Patient Safety Risk of burns from faulty return pad or insulation failure Minimized risk of patient burns and ideal for patients with implants
Voltage Typically uses higher voltages for effective cutting and blend modes Uses lower voltages, delivering less energy
Invasive Level Suitable for both open surgery and minimally invasive procedures Excellent for minimally invasive and delicate surgical procedures

Advancements in Electrosurgical Technology

Modern electrosurgical units (ESUs) offer advanced features like instant response technology that adjusts power based on tissue impedance, improving safety and precision. Innovations in bipolar devices, such as integrated cutting blades, address some traditional limitations. These advancements contribute to safer and more effective surgical outcomes.

Outbound Link

For additional regulatory and safety guidelines on electrosurgical devices, consult the official FDA resources: 510(k) Submissions for Electrosurgical Devices for General Surgery.

Conclusion

Understanding the fundamental differences between monopolar and bipolar electrosurgery is crucial for modern surgical practice. Monopolar offers versatile cutting and coagulation for large areas but carries a higher risk due to the current passing through the patient's body. Bipolar provides a safer, more focused effect for precise coagulation by confining the current within the surgical instrument. The choice between the two depends on the surgical application, the size of the tissue area, and the patient's specific health considerations, especially the presence of any implanted electronic devices. Recent technological improvements continue to refine these techniques, pushing the boundaries of what's possible in surgical precision and safety.

Frequently Asked Questions

The main difference lies in the electrical current's path. In monopolar electrosurgery, the current passes through the patient's body to a dispersive pad. In bipolar electrosurgery, the current is contained within the instrument, passing only through the tissue being treated.

Bipolar electrosurgery is the safer option for patients with pacemakers or other implanted electronic devices. The current does not pass through the patient's body, minimizing the risk of interference or device malfunction.

While some advanced bipolar devices now incorporate a mechanical blade for cutting, traditional bipolar electrosurgery is not effective for cutting tissue. It is primarily used for precise coagulation.

Improper placement or inadequate contact of a monopolar dispersive pad can lead to a condition where the electrical current exits the patient's body through a much smaller, unintended area. This can cause a severe thermal burn at the exit site.

The electrosurgical generator (ESU) is the power source that modulates the electrical current from a standard power outlet to a high-frequency current suitable for surgical applications, preventing neuromuscular stimulation.

Monopolar electrosurgery uses different waveforms and power settings to achieve various tissue effects. A continuous, unmodulated waveform is used for a precise 'cut,' while an interrupted, modulated waveform with higher peak voltage is used for more significant coagulation.

In delicate procedures, bipolar electrosurgery offers significant benefits by providing greater control and minimizing collateral thermal damage. The energy is localized strictly to the tissue grasped by the instrument, protecting surrounding sensitive structures.

References

  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9

Medical Disclaimer