Skip to content

What is not recommended for plasma sterilization?

4 min read

Plasma sterilization, a low-temperature process often using vaporized hydrogen peroxide, is highly effective for heat-sensitive instruments, but it's not a universal solution. Understanding exactly what is not recommended for plasma sterilization is critical to prevent damage, ensure efficacy, and maintain safety standards in healthcare settings.

Quick Summary

Highly absorbent items, like cellulose-based materials, liquids, and powders, are incompatible with plasma sterilization because they can absorb the sterilant and hinder the process. Additionally, certain devices with restricted lumens or specific metals that can degrade are unsuitable for this method.

Key Points

  • Absorbent materials: Avoid sterilizing items made from cellulose, such as paper, cardboard, and cotton textiles, as they absorb the sterilant and reduce effectiveness.

  • Liquids and Powders: The process is not suitable for liquids or powdered substances, which can absorb the sterilant and prevent proper penetration.

  • Long, Narrow Lumens: Plasma's penetration can be limited in devices with complex shapes or long, thin internal channels, which may require an alternative method.

  • Incompatible Metals: Certain metals like copper, bronze, and zinc can react negatively with the sterilant and should not be processed.

  • Wet Items: All items must be completely dry before a cycle begins, as any residual moisture can lead to a sterilization failure.

  • Incompatible Packaging: Use only manufacturer-recommended synthetic packaging, like Tyvek®, not cellulose-based materials intended for steam sterilization.

In This Article

Understanding the limitations of plasma sterilization

Plasma sterilization, particularly hydrogen peroxide gas plasma, is a cornerstone of modern infection control, especially for delicate medical instruments that cannot withstand the high heat of steam autoclaving. The process involves ionizing a gas, often hydrogen peroxide vapor, to create a plasma field of highly reactive free radicals that destroy microorganisms. However, the efficacy of this method is dependent on the type of material and the design of the object being sterilized. The limitations are primarily due to the physical and chemical properties of the sterilant and the process itself.

Highly absorbent materials

One of the most significant restrictions for plasma sterilization is the use of highly absorbent, or cellulosic, materials. These include:

  • Paper
  • Cardboard
  • Cotton, cloth, and linen textiles
  • Anything made of wood or similar plant-based fibers

These materials can absorb the hydrogen peroxide vapor, drastically reducing the concentration of the sterilant available to actually kill microorganisms in the chamber. This can lead to sterilization failures and is the primary reason why standard paper-plastic pouches or textile wraps for steam sterilization are not compatible with hydrogen peroxide plasma systems. Instead, specialized non-porous synthetic wraps and pouches, such as those made with Tyvek®, are required to allow the plasma to penetrate while still maintaining a sterile barrier.

Liquids and powders

The plasma sterilization process is designed to work in a low-pressure, gaseous environment. For this reason, liquids and powders are not recommended. Liquids can impede the vacuum cycle and are incompatible with the vapor phase of the sterilant. Powders, on the other hand, can absorb the sterilant and may also clump together, preventing proper penetration and contact with all surfaces. Any moisture left on an instrument after pre-cleaning can also cause a sterilization failure and result in a “wet load”. Therefore, all items must be thoroughly cleaned and dried before being placed in the plasma sterilizer to ensure success.

Instruments with restricted lumens

The ability of plasma to penetrate complex geometries is a known limitation. Instruments with long, narrow lumens or tiny crevices can be difficult to sterilize effectively, as the reactive plasma species may not reach the innermost surfaces in sufficient concentration. The Centers for Disease Control and Prevention (CDC) has noted that some endoscopes and medical devices with very specific lumen restrictions may not be suitable for plasma sterilization. Medical device manufacturers provide specific guidelines for the maximum length and internal diameter of lumens that their devices can safely undergo the process. It is crucial to consult these manufacturer's recommendations before attempting to sterilize such instruments.

Incompatible metals and materials

While plasma is generally compatible with many materials, certain metals and other compounds are not. Oxidative reactions from the hydrogen peroxide vapor and plasma can cause corrosion or material degradation over time. Incompatible metals include:

  • Zinc
  • Tin
  • Nickel
  • Bronze
  • Copper

These metals can react adversely with the sterilant, causing damage to the instruments. Additionally, some dyed elastomers and plastics may experience mild discoloration or yellowing after repeated exposure to the plasma process. Manufacturers must perform thorough material compatibility testing to ensure that their products can withstand repeated sterilization cycles without degradation.

Comparison of sterilization methods

To provide context on the alternatives, the following table compares key aspects of hydrogen peroxide gas plasma sterilization with traditional steam sterilization (autoclaving), one of the most common methods.

Feature Hydrogen Peroxide Plasma Sterilization Steam Sterilization (Autoclaving)
Temperature Low (<50°C) High (>121°C)
Processing Time Relatively fast (30-75 min) Moderate to fast (15-60 min)
Toxic Residues None; byproduct is water vapor and oxygen None
Material Compatibility Good for heat/moisture-sensitive items; incompatible with cellulose, liquids, some metals Incompatible with heat/moisture-sensitive items; good for most others
Penetration Limited, especially in long, narrow lumens Excellent, high-pressure steam penetrates porous loads
Compatibility Issues Cellulosic materials, liquids, powders, some metals Heat-sensitive polymers, electronics, optics

For additional regulatory standards and guidance on medical device sterilization, the U.S. Food and Drug Administration (FDA) is an authoritative source. Their recognition of consensus standards helps ensure safety and innovation in the field.

Conclusion

While plasma sterilization offers an invaluable low-temperature solution for a wide range of medical devices, it is not a one-size-fits-all process. A clear understanding of what is not recommended for plasma sterilization is essential for any facility using this technology. The incompatibility with absorbent materials like paper and textiles, liquids, powders, and specific metals are critical constraints. Furthermore, instruments with intricate, narrow lumens can present a challenge. By adhering to manufacturer guidelines and process limitations, healthcare professionals can ensure effective sterilization and prevent costly damage to sensitive equipment.

For more information on the various sterilization techniques available, including the proper handling and validation procedures, the Centers for Disease Control and Prevention provides comprehensive resources on sterilization best practices in healthcare.

Frequently Asked Questions

No, you cannot. Cellulosic materials like paper, cardboard, cotton, and linen are highly absorbent and will absorb the vaporized hydrogen peroxide, leading to a failed sterilization cycle. Non-porous, plasma-compatible materials are required for packaging.

Placing a liquid in a plasma sterilizer is not recommended. The low-pressure vacuum cycle is designed for vapor, not liquids, and their presence can interfere with the process, causing a cycle to abort and potentially damaging the machine.

Some metals, such as copper, bronze, and zinc, are incompatible because they can oxidize or corrode during the process due to the reactive nature of the plasma and hydrogen peroxide vapor. These reactions can damage the instrument and interfere with the sterilization.

Yes. Due to the limited penetration power of the plasma, there are restrictions on the length and diameter of lumens. For instance, some endoscopes with particularly long and narrow channels are not compatible. Always check the manufacturer's instructions for specific limitations.

No, items must be completely dry. Any moisture can create a wet load, which can compromise the sterilization cycle's effectiveness. Proper drying is a crucial pre-cleaning step.

A major advantage is that plasma sterilization operates at a low temperature, making it ideal for delicate, heat-sensitive instruments like many plastics, electronics, and optical devices that would be damaged by high-heat steam.

Yes, it is considered environmentally friendly. The sterilant, typically hydrogen peroxide, breaks down into non-toxic byproducts of water vapor and oxygen at the end of the cycle, leaving no harmful residues.

References

  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8

Medical Disclaimer

This content is for informational purposes only and should not replace professional medical advice.